Conductor - Element 1 (Power/Control) 18 AWG 2C Unshielded |
AWG Size & Stranding | 18 AWG 16 Strands |
Material | Annealed Tinned Copper |
Conductor Count | 2 Conductors |
Insulation - Element 1 (Power/Control) 18 AWG 2C Unshielded |
Material | Polyvinylchloride (PVC) |
Wall Thickness | 0.007” |
Color Code | Black, Red |
Conductor - Element 2 (Data) 22 AWG 1Pr Shielded |
AWG & Stranding | 22 AWG 7 Strands Class B |
Material | Annealed Bare Copper |
Conductor Count | 1 Pair |
Insulation - Element 2 (Data) 22 AWG 1Pr Shielded |
Material | Foam Polyethylene (PE) |
Wall Thickness | 0.020” |
Color Code | Blue, White |
Assembly - Element 2 (Data) 22 AWG 1Pr Shielded |
Pair Lay Length | Cabled on Common-Axis with Element 2 |
Pair Drain Wire | 24AWG 7/32 Strand Tinned Copper (Inside Foil) |
Pair Shield | Aluminum/Mylar Tape – 100% Coverage (Foil Facing Inside) |
Assembly – Elements 1 & 2 - Overall Cable Assembly for Element 1 & 2 |
Cable Lay Length | 3.50” LHL (3.43 tw/ft) |
Jacket – Overall Cable Assembly for Element 1 & 2 |
Material | Polyvinylchloride (PVC) |
Wall Thickness | 0.035" |
Diameter | 0.245” |
Color | Black |
Ripcord | Yes |
Weight | 38 lbs/Mft |
Markings – Overall Cable Assembly for Element 1 & 2 |
Type | Cable permanently identified via surface inkjet print |
Legend | AVALANCHE MFG. FOR AMX AX-LINK ™ CABLE ROOM A B C D E 0 1 2 3 4 5 6 7 8 9 E171197 18AWG 2C NETWORK & 22AWG 1PAIR SHLD DATA (UL) CM C(UL)US OR C(UL)US CL3 75’C (WORK ORDER #) “ROHS” |
Footage Markers | Yes |
Nominal Electrical Characteristics - Overall Cable Assembly for Element 1 & 2 |
Characteristic Impedance | 22AWG: 105 Ω - 18AWG: 55.2 77 Ω |
Mutual Capacitance | 22AWG: 12.5 pF/ft - 18AWG: 36.76 pF/ft |
DC Resistance | 14.8 Ω/Mft @ 20°C - 18AWG: 6.39 Ω/Mft @ 20’C |
Standards - Overall Cable Assembly for Element 1 & 2 |
Maximum Operating Voltage | 300V |