Copper Price 11/19/2024 4.0960
Two element composite cable with an overall plenum rated PVC jacket. For AMX AX-LINK Network and Automation Control Applications
SKU: AVPAXLINK-00
 

• (2C) 18 AWG 16 Strands TC SGPVC Insulated Unshielded
• (1P) 22 AWG 7 Strands BC Foamed FEP Insulated Shielded


• UL listed as CMP c(UL)US per UL standard 444 and CL3P per UL standard 13
• All materials used in the manufacturing of this cable are RoHS II & REACH compliant
• Made in the USA

This spec is for informational purposes and subject to change. This spec may not be suitable for submission. Contact Lake Cable for non-watermark spec sheet.
Products specifications
Attribute nameAttribute value
Conductor - Element 1 (Power/Control) 18 AWG 2C Unshielded
AWG Size & Stranding18 AWG 16 Strands Class K
MaterialAnnealed Tinned Copper
Conductor Count2 Conductors
Insulation - Element 1 (Power/Control) 18 AWG 2C Unshielded
MaterialPlenum Rated Polyvinylchloride
Wall Thickness0.007”
Color CodeBlack, Red
Conductor - Element 2 (Data) 22 AWG 1Pr Shielded
AWG & Stranding22 AWG 7 Strands Class B
MaterialAnnealed Bare Copper
Conductor Count1 Pair
Insulation - Element 2 (Data) 22 AWG 1Pr Shielded
MaterialFoamed FEP
Wall Thickness0.020”
Color CodeBlue, White
Assembly - Element 2 (Data) 22 AWG 1Pr Shielded
Pair Lay LengthCabled on Common-Axis with Element 1
Pair Drain Wire24 AWG 7 Strand Tinned Copper (Inside Foil)
Pair ShieldAluminum/Mylar Tape – 100% Coverage (Foil Facing Inside)
Assembly – Elements 1 & 2 - Overall Cable Assembly for Element 1 & 2
Cable Lay Length2.50” LHL (4.8 tw/ft)
Jacket – Overall Cable Assembly for Element 1 & 2
MaterialPlenum Rated Polyvinylchloride
Wall Thickness0.015”
Diameter0.187”
ColorBlack
RipcordYes
Weight31 Lbs/Mft
Markings – Overall Cable Assembly for Element 1 & 2
TypeCable permanently identified via surface inkjet print
LegendAVALANCHE(TM) PLENUM AMX AX-LINK™ CABLE ROOM A B C D E 0 1 2 3 4 5 6 7 8 9 E171197 18AWG 2C NETWORK & 22AWG 1PAIR SHLD DATA (UL) CMP C(UL)US OR (UL) CL3P OR (UL) FPLP 75’C FT-6 “ROHS II” MADE IN USA
Footage MarkersYes
Nominal Electrical Characteristics - Overall Cable Assembly for Element 1 & 2
Characteristic Impedance22AWG: 105 Ω - 18AWG: 57 Ω
Mutual Capacitance22AWG: 12.5 pF/ft - 18AWG: 33 pF/ft
Conductor DCR (Max)22AWG: 16.6 Ω/Mft @ 20°C - 18AWG: 6.94 Ω/Mft @ 20°C
Operating Voltage300V RMS Maximum

Remember, all of our wire can feature:

  • Short minumum runs
  • Special jacket colors including stripes
  • Custom print legends
  • Custom cable constructions
  • Custom packaging - boxes or reels
  • Custom lengths
  • Your name on package labels