Copper Price 12/20/2024 4.0325
16 AWG 2 pairs solid type KX thermocouple extension wire, PVC insulation, shielded pairs and overall shield, with an overall PVC jacket for PLTC and ITC 105’C
SKU: TK162SPOS
 
• Cable meets IEEE 383 & UL 1581 (1685) 70,000 BTU/HR flame test requirements
• All materials used in the manufacture of this cable are RoHS compliant
• Made in the USA
• UL listed as type PLTC Sunlight Resistant per UL standard 13 and as type ITC per UL standard 2250
This spec is for informational purposes and subject to change. This spec may not be suitable for submission. Contact Lake Cable for non-watermark spec sheet.
Products specifications
Attribute nameAttribute value
Conductor
AWG Size & Stranding16 AWG Solid
MaterialType KP (Chromel) & Type KN (Alumel)
Conductor Count2 Pairs
Insulation
MaterialPolyvinylchloride
Wall Thickness0.016”
Color CodeYellow (KP) & Red (KN) Numbered
Assembly
Pairs Lay Length2.50” LHL (4.8 Tw/Ft)
Pairs Drain Wire18 AWG 7 Strand Tinned Copper Inside
Pairs ShieldFoil Free Edge Aluminum/Mylar – 100% Coverage
Cable Lay Length4.50” LHL (2.67 Tw/Ft)
Cable BinderClear Mylar Tape Wrap – 100% Coverage
Cable ShieldAluminum/Mylar Tape – 100% Coverage
Drain Wire16 AWG 7 Strand Tinned Copper
Jacket
MaterialPolyvinylchloride
Wall Thickness0.040”
Diameter0.370”
ColorYellow
RipcordYes
Weight92 Lbs/Mft
Markings
TypeCable permanently identified via surface inkjet print
LegendLAKE CABLE E171202 16AWG 2PR SPOS (UL) PLTC OR (UL) ITC 105’C PVC TYPE KX EXTENSION GRADE THERMOCOUPLE PVC JACKET SUN RES DIR BUR FT-4 “ROHS”
Footage MarkersYes

Remember, all of our wire can feature:

  • Short minumum runs
  • Special jacket colors including stripes
  • Custom print legends
  • Custom cable constructions
  • Custom packaging - boxes or reels
  • Custom lengths
  • Your name on package labels